Current Category Pumps and Parts > Pumps > Pumps - Spa Circulation Pumps > Laing
 


Laing Thermotech spa circulation pumps

Spa Circulation Pumps - low flow and high flow - Laing Thermotech for Sundance Spas, Hot Spring Spas, LA Spas, Heritage Spas, Maax Spas, Lanark Spas, Southwest Spas, Sierra Spas, Dimension One, and many others. Circulation pumps in spas can drive the filtration, heating and ozone systems, or ozone circulation alone.
Electrical rating of all pumps unless otherwise listed - 240v, 50Hz





Laing Thermotech 88w Seal-less Centrifugal Canned Motor Spa Circulation Pump - SM-959-NH-26 - Metal Mount - Old wetend l 68219-o Laing Thermotech 88w Seal-less Centrifugal Canned Motor Spa Circulation Pump - SM-959-NH-26 - Metal Mount - Old wetend

NO LONGER AVAILABLE - USE E-10 PUMP BELOW
Original style - up to 2007 - metal mounting bracket, original design wetend
Differs from new version by mounting type, length of inlet/outlet barbs, and the internal seal arrangement.
If you are replacing the pump on a spa fitted with a wetend mounted circulation heater, you'll need to order this version, otherwise heater replacement will also be required.
Laing Sealless centrifugal canned motor pump SM-959-NH-26 plastic housing.
Magnetic driven circulation pump - duty rated (24hr) 88W power rating - 1/20th HP.
Fitted with mini JJ plug/cord
Can be used in all circulation filtration, heating and ozone applications
3/4" barb connection
Max. fluid temperature - 60 degrees C / 140 degrees F
Mounting - horizontal, or vertical with motor at the bottom - no other angles are permitted.
1 year warranty
Used on numerous brands of spas with various names - Silent Flo 5000 by Hot Springs Spas, Dimension One Spas, LA Spas, Sundance Spas, Southwest Spas, Sierra Spas and many others
220-240v, 50Hz, 30 lpm
Note - Dry running (insufficient water) will result in pump failure due to overheating the impeller bearing/seal system which relies on water for lubrication. Warranty does not cover this event. Ensure water flows after initial installation, after refilling, and after filter cleaning. If not, clear the air lock by loosening the tubing connected to the pump until water leaks out. Retighten and check flow.



Laing Circulation Pump Installation & Operating Manual

AUD



Use L P3020 Below



Laing Thermotech 88w Seal-less Centrifugal Canned Motor Spa Circulation Pump - SM-959-NH-26 l 68219 Laing Thermotech 88w Seal-less Centrifugal Canned Motor Spa Circulation Pump - SM-959-NH-26

NO LONGER AVAILABLE
Use new E-10 pump below - supercedes this pump

New design wet end 2007.
Laing Sealless centrifugal canned motor pump SM-959-NH-26 plastic housing.
Magnetic driven circulation pump - duty rated (24hr) 88W power rating - 1/20th HP. 30lpm maximum flow.
Fitted with mini JJ plug/cord
Can be used in all circulation filtration, heating and ozone applications
3/4" barb connection
Max. fluid temperature - 60 degrees C / 140 degrees F
Mounting - new design wet end with plastic mounting feet arrangement allows for universal mounting positions - horizontal, vertical or every 45 degrees, (vertical with motor at the bottom - no other angles are permitted).
1 year warranty
Used on numerous brands of spas with various names - Silent Flo 5000 ( Hot Springs Spas ), Dimension One Spas, LA Spas, Sundance Spas, Southwest Spas, Sierra Spas and many others
220-240v, 0.9A, 50Hz, 30 lpm, less than 30db noise level.
Note - Dry running (insufficient water) will result in pump failure due to overheating the impeller bearing/seal system which relies on water for lubrication. Warranty does not cover this event. Ensure water flows after initial installation, after refilling, and after filter cleaning. If not, clear the air lock by loosening the tubing connected to the pump until water leaks out. Retighten and check flow.



Laing Circulation Pump Installation & Operating Manual

AUD



Use L P3020 Below



Laing Thermotech E-10 Circulation Pump 3/4" Barbed - Mini JJ Cordset l p3020 Laing Thermotech E-10 Circulation Pump 3/4" Barbed - Mini JJ Cordset
Laing Thermotech E - 10 electronically commutated canned spherical motor centrifugal spa circulation pump
60 lpm flow maximum, 6.5m head maximum (double the flow of the standard l 68219 pump listed below)
3/4" barb connections
E-10-NSHN2W-20 4' TSP-103L
230v, 0.3A, 70w, 50/60Hz, 3200 rpm, less than 40 db noise level
4 ft Mini JJ Cordset fitted.
P7220020_sml.jpg
Price:
AUD







QTY:
Laing Thermotech E-10 Circulation Pump 3/4" Barbed - AMP Cordset l 73479 Laing Thermotech E-10 Circulation Pump 3/4" Barbed - AMP Cordset
Laing Thermotech E - 10 electronically commutated canned spherical motor centrifugal spa circulation pump
60 lpm flow maximum, 6.5m head maximum (double the flow of the standard l 68219 pump listed below)
3/4" barb connections
E10-NSHN2W20 4' Amp
230v, 0.3A, 70w, 50/60Hz, 3200 rpm, less than 40 db noise level
4 ft AMP Cordset fitted.
P7220020_sml.jpg
Price:
AUD







QTY:
Laing Thermotech E-14 High Flow Circulation Pump 1.5" unionised l 73349 Laing Thermotech E-14 High Flow Circulation Pump 1.5" unionised

Laing Thermotech E - 14 electronically commutated canned spherical motor centrifugal spa circulation pump
High flow circulation pump designed for flow through heater applications.
Can be used in place of Aquaflo CMCP Circ Master pumps
130 lpm flow maximum, 3m head maximum
1.5" threaded unionised connections - complete with unions
230v, 0.43A, 98w, 50/60Hz, 2100 rpm, less than 50 db noise level
AMP plug/cord standard


Price:
AUD







QTY:
Laing Thermotech Circulation Pump Impeller Assembly - Suits early models only laingimp Laing Thermotech Circulation Pump Impeller Assembly - Suits early models only

Laing circulation pump impeller assembly - SUITS OLDER LAING PUMPS WITH 8MM DIAMETER CERAMIC 'BALL/KNOB' BEARING ONLY - newer pumps have much wider diameter ceramic bearings and do not accomodate this impeller assembly.
Noryl impeller with Carbon Graphite bearing cap
Suits SM-959-26 240V, 50Hz Laing Thermotech Seal-less Centrifugal Canned Motor Spa Circulation pumps.
The impeller requires replacement if it becomes noisy or unbalanced as a result of dry running or bad chemistry - the carbon graphite bearing cap wears out or melts when overheated. Ensure proper water flow to prevent impeller failure


Price:
AUD







QTY:

 

 

Home | Featured Product | Contact Us | Information | Manufacturers Links | Trade Enquires | Downloads | Spa Error Codes | Sauna Information | Universal Currency Converter | Search | View Cart | New Products | International Customers | E-Bay Australia Spa Buyer Warning

© 2008 Australian Spa Parts Pty Ltd. All rights reserved.